New Features - inter-program collaboration - copy/paste - one-page summary printouts - Barium & Strontium compounds in WaterCycle ![]() |
Water reuse and green chemistry are more important than ever. French Creek programs now collaborate - allowing you to mix and copy water between programs. Find out how your RO reject performs in your cooling tower or check compatibility when disposed of in an injection well. Blend streams within a plant and model their use in cooling water, RO, or other applicaitons. |

free demo | pdf manual | online store
WaterCycle Walkabout
PDF tour
Since it's release in 1990, WaterCycle® and the Rx family have quickly become the international standard in cooling water modeling and treatment software.
From predicting scale and corrosion, formulating new products, to even global marketing campaigns (corporate licensing), WaterCycle has revolutionized how water is treated and how treatment chemicals are sold.
Using WaterCycle, users are able to quickly input a complete water analysis (in whichever analytical units they choose), thoroughly troubleshoot scale and corrosion, then find a dosage of appropriate scale and corrosion inhibitors.
WaterCycle uses an ion association model to extend the applicable ionic strength for calculations, and to provide consistent, reproducible indices for common, and not so common, scale forming species.
WaterCycle's different modules give treatment specialists the ability to model scale, corrosion, and inhibitor dosages over their entire operating range, any range of pH or concentration. The saturation index and color coded visual aids show exactly where chemistry becomes questionable and where treatment is needed.
![]()
WaterCycle's greatest strength is translating sophisticated, PhD level chemistry into easily understandable graphs and tables a novice water treater with one semesters of 101 Level University Chemistry can understand.
During an analysis, a tremendous amount of information is produced. A water treatment provider can dive into the numbers and thoroughly review the chemistry and when changes occur.

If in a crunch or in need of a simpler way to follow the results, users can choose from a number of 2D and 3D color coded graphs, each highlighting a separate or similar feature in your system's operating range.
Fool
proof your reports and treatment recommendations with
two-dimensional graphs. 2D color coded graphs display
chemistry in a more concise medium.
The color coding allows users to pinpoint at what concentration/cycle, pH or temperature a specific scale or index predicts scale - after just a quick glance at the screen.
Take your reporting a step further and select the "Common Foulants" group to display four graphs at once featuring Calcite, Silica, Calcium phosphate and Anhydrite saturation levels (French Creek's ion association saturation index).
![]()
Three-dimensional
graph's present three different variables over a selected range of pH,
concentration, temperature, or saturation.
Graph's are color coded to show where treatment is needed or a treatment's limits.
Zeroing in on a specific range is simple. With a few clicks and keystrokes, adjust the parameters you want for a narrower or broader view.
WaterCycle calculates a wide range of scale forming species, from typical Calcium carbonate to scales only present under certain conditions like Barium.
See where a particular scale will form in your system and at what specific parameters using French Creek's Calculation Engine, powered by an ion association model
WaterCycle models the following saturation levels using French Creek's powerful ion association model.
Other indices calculated by WaterCycle
Langelier Saturation Index
Ryznar Stability Index
Practical (Puckorius) Scale Index
Larson-Skold Corrosivity Index
WaterCycle Rx (premium editions) include a module for modeling corrosion rates.
WaterCycle uses a combination of laboratory, field and experiential data in its corrosion module.
Very similar to WaterCycle's scale prediction functions, the corrosion module evaluates a system under varying conditions to determine the impact of operating parameter changes (e.g. acid feed, concentration ratio, pH) upon water corrosivity and corrosion inhibitor requirements.
WaterCycle comes with a model for 1010 Carbon Steel, but you
can develop your own profiles using field and lab data using
a Laboratory edition.
Also See product formulation
pH Control Options
Acids
Alkalis
Common sense indicates that the same scale inhibitor dosage is not required for all waters and systems.
One size does not fit all.
Using field data, laboratory data, and common sense collected over decades - WaterCycle calculates inhibitor dosages and their effective operating range.
WaterCycle creates helpful color coded graphs to easily view how your systems will react to treatments:

![]()



![]()
The makers of WaterCycle realize each company uses their own blend of inhibitors and are frequently trying to optimize for performance and cost.
WaterCycle Product Manager and Laboratory Editions allow custom input of inhibitors and ratios.
Sound confusing? Rest assured it's quite simple to build and maintain Product Files (.prd extension) for use in your own and other's WaterCycle editions.
WaterCycle comes preloaded with all widely used and available inhibitors for your custom formulations. Don't see an inhibitor you are looking for below? Ask, chances are we have have a model for it or an equivalent.
Also, you can always build your own inhibitor files using your own field and lab data and a Laboratory Edition.
Calcium carbonate Inhibitors
AMP (amino tris methylene phosphoric acid) | Dequest 2000
HEDP (hydroxy ethylidene diphosonic acid) | Dequest 2010
PBTC (phosphono butyl tricarboxylic acid) | Bayhibit AM
PAA (polyacrylic acid, low molecular weight) | Acumer 1000, AR-900A
POCA (phosphono carboxylic acid) | Belclene 494
PMA (poly maleic anhydride) | Belclene 494
Modified PMA | Belclene 283
Calcium phosphate inhibitors
AA-AMPS | Acumer 2000
Proprietary terpolymer | Acumer 3100
Proprietary | Aquatreat 540
Proprietary terpolymer | Goodrite K-798
Generic SSMA (sulfonated styrene maleic anhydride) | Versa TL-7
Calcium sulfate inhibitors
PCA (phosphono carboxylic acid) | Belsperse 161
Generic PAA
Silica inhibitors
Proprietary | Acumer 5000
Corrosion inhibitors
Orthophosphate
PCA (phosphono carboxylic acid) | Belcor 575
molybdate
Corrosion rate models
mild steel | untreated
Acknowledgments
Acumer is a trademark of the Rohm and Haas Company
Aquatreat is a trademark of the ALCO Chemical Division of National Starch
Belclene, Belcor, Belsperse, and Flocon are all trademarks of BWA Water Additives.
Dequest is a trademark of Monsanto Chemical Company
Goodrite is a trademark of the BFGoodrich Company
Versa is a trademark of the National Starch and Chemical Company
WaterCycle and WaterCycle Rx are trademarks of French Creek Software
A tool like WaterCycle was once the dream of early water treatment pioneers like Langelier and Ryznar (whose namesakes are well associated with their widely used simple indices).
At the time sophisticated calculations and indices were limited to computing power.
WaterCycle gives its users the tool Langelier and Ryznar were describing in their early and groundbreaking papers where they introduced their indices - as an alternative until such a technology were available.
What they described was a powerful, reproducible means to predict scale, corrosion and inhibitor dosages using ion pairing, while accounting for common ion affects.
WaterCycle uses an ion association model to estimate the saturation level (ion activity product over solubility product) for common foulants including calcium carbonate, calcium sulfate, amorphous silica, calcium fluoride, magnesium silicates, and tricalcium phosphate.
The calculation engine packs some serious punch. Each point on a graph is calculated through 120 non linear equations - twice. Saturation is modeled through over 100 ion pairs, far beyond the capabilities and accountabilities of simple indices.
Choose from the basic edition which calculates only saturation indices to the premium Rx Series.
Also see "Premium Editions"
The Salesman Edition performs all of the functions and has all of the features of the basic WaterCycle program. It adds the ability to select a water treatment product and obtain dosage recommendations. Each table has an additional line for Dosage or Predicted Corrosion Rate in the Rx series, of which the Salesman Edition is the first. An additional graph selection appears for all two (2D), three (3D), and four (4d) dimensional graphs - the Dosage Profile.
The Salesman edition can load a Product File (.PRD) for use in determining treatment rates and developing dosage profiles. But, alas, the Salesman Edition lacks the ability to edit or create Product Files, or even look at the ingredients. They must be created (and edited) using a higher member of the WaterCycle Rx Series. Both the Product Manager and Laboratory Editions can create and edit Product Files.
Salesman Editions are used extensively by field sales and service engineers, and by plant chemists for optimizing treatment levels.
The Product Manager Edition adds the ability to create and edit product files. Creating a Product File is as simple as filling in a computerized formula (batch) sheet. Product Files can be password protected to maintain confidentiality. Files so created can be used by the Product Manager Edition or copied to the \WATER\INHIB sub-directory on other computers with WaterCycle Rx programs.
Product Manager Editions are used extensively by water treatment companies who wish to use the inhibitor models supplied by French Creek, by Corporate Chemists who wish to evaluate and compare the treatment programs proposed for their cooling systems, and by consultants for performing in-depth technical and economic analyses of aqueous systems.
The Laboratory Edition adds the ability to develop scale inhibitor, corrosion inhibitor, and corrosion rate predictive models from laboratory data, field data, or a combination of both. Dosages (or Rates) can be modeled as a function of any parameters input into the program in their raw form, calculated indices, and other parameters calculated by the program.
Transforms are available and can be applied independently to each variable. For example, a CaCO3 inhibitor might be modeled:
- log(DOSAGE) = f( log(Calcite Saturation - 1), 1./RT, log(time))
This is, in fact, a common model for phosphonate inhibitors.
A simple corrosion rate model might be correlated as follows:
- log(Rate) = f( log(Ca), 1./RT, log(Cl), log(SO4 ), pH)
Inhibitor models developed by the Laboratory Edition are output to the .INH files used to develop Product Files. Raw data is stored in .COR files. Statistics are, of course, provided on each variable as you develop a model.
Laboratory Editions are used extensively by scale inhibitor synthesizers, and by major water treatment companies and industrial laboratories doing inhibitor and/or corrosion research.
Five of the top six U.S. water treatment service companies, as ranked by sales volume, use the Laboratory Edition. It is used by all of the major inhibitor suppliers, and by the top industry consultants. Isn't it time for you to add WaterCycle Rx to your technical arsenal?
| Basic edition |
Field Engineer/ Salesman |
Formulator/ Product Manager |
Laboratory | |
| Calculate Saturation Levels, Indices |
|
|
|
|
| Profiles 2D & 3D Graphs |
|
|
|
|
| Optimize Dosages Using Existing Product Files |
|
|
||
| Create Product Files, Input Custom Formulations |
|
|
||
| Develop Inhibitor Models for Incorporation into Product Files |
|
|||
| Develop Corrosion Rate Models |
|
About | Products | Corporate Profile
Copyright © 2009 French Creek Software. All Rights Reserved. The following are trademarks of French Creek Software Inc. and may only be used with permission: French Creek, French Creek Software, WaterCycle, WaterCycle Rx, hyd-RO-dose, hyd-RO-sat, DownHole SAT, WatSIM and MineSAT. The absence of a name or logo in this list does not constitute a waiver of any and all intellectual property rights that French Creek Software has established in any product, feature, or logos.

